Thermocouple 2304885 Dyna Glo 40-150K btu LP 1130/1474

This 2304885 thermocouple is used in all of the forced air LP heaters sold by GHP.  

When you let go of the button on the gas valve and the heater won't ignite, three parts may cause this problem. The thermocouple, the valve itself and a heat limit switch if your heater has one. Of these three parts, about 80% of the time its a bad thermocouple causing the problem.

Brands include Dyna Glo, Thermoheat and Dyna Glo Pro

Models Included: FA40DGD, FA40DGP, FA40DGP-01, FA50DGD, FA50DGP, FA50DGP-01, FA60DGD, FA60DGP, FA60DGP-01, FA100DGD, FA100DGP, FA100DGP-01, FA125DGD, LPFA125DGD, FA125DGP, FA125DGP-01, FA150DGD, FA150DGP, FA150DGP-01

The thermocouple is 17" long. The wire is 5" long.